AMP-22 is our new generation AC charging station to supply electricity to an EV. It has compact and modern design for your home and company charging use. The EVSE can connect to your mobile phone via Bluetooth App. You can operate and monitor the charging status remotely.
AMP-22 is our new generation AC charging station to supply electricity to an EV. It has compact and modern design for your home and company charging use. The EVSE can connect to your mobile phone via Bluetooth App. You can operate and monitor the charging status remotely.
Technical specifications
Product specifications at a glance
Key parameters are grouped by function so buyers can compare power, installation, connectivity, protection, certification, and operating conditions without reading an unstructured text block.
Electrical Performance
Input voltage
380Vac±20%,50±3Hz,3-phase + Neutral + PE
Power factor
0.99 at nominal output
RCCB
Type-A + 6mA DC
Rated output power
22KW
Outlet type
IEC 62196 Type-2
Output voltage range
400Vac
Output current range
0-32A
Charging outlet
Type-2 socket with electrical lock
Display
TFT touch screen
System & Installation
Charging type
Mode 3
Dimension ( H x W x D )
222 x 104 x 405mm
Enclosure protection grade
IP65
Installation method
Wall mount, Pedestal mount
Cable routing
Bottom or Top inlet wiring
Net weight
3.62kgs
Charging standard
IEC 61851-22
Certificate
CE by DEKRA
Display & Connectivity
User authentication
App interface
Interface languages
English (other Languages upon request)
Network interface
Wi-Fi, Bluetooth, 4G(optional)
Environmental & Protection
Working temperature
-25°C – +50°C
Storage temperature
-25°C – +70°C
Altitude
<2000m
Cooling
Natural cooling
The protection grades
IP65/IK10
Ten Protection
Emergency shutdown
Overcurrent protection
Overvoltage protection
Undervoltage protection
Leakage protection
Grounding protection
Temperature protection
Waterproof protection
Power-off protection
Project fit and buyer notes
22KW Socket TFT Touch Screen for EV charging projects
22KW Socket TFT Touch Screen can be evaluated as part of Amprisen's AC EV charger range. Confirm connector, power, network, certification, branding, and installation requirements before quotation so the final configuration matches the target market and deployment scenario.
Short answer: 22KW Socket TFT Touch Screen should be evaluated by power level, connector standard, socket or cable output, communication method, certification market, installation scenario, and whether the buyer needs private or managed charging.
Specification focus for buyers
Decision area
What to confirm
Power and phase
Confirm 7kW single-phase or 11kW/22kW three-phase charging based on grid capacity and vehicle onboard charger.
Connector and output
Select Type 1, Type 2, GBT, or NACS planning, then choose socket or tethered cable output.
Smart functions
Confirm OCPP, RFID, app control, DLB, WiFi, Bluetooth, Ethernet, or 4G only when the site needs managed operation.
Metering and protection
Check Dynamic Load Balancing for shared power sites, MID metering for billing or reimbursement, and RCD requirements such as Type A, Type B, or 6mA DC leakage protection.
Use case
Separate private home charging from apartment, hotel, workplace, parking operator, and fleet scenarios.
Typical applications
Residential charging
Workplace charging
Apartment and hotel parking
Commercial parking and destination charging
Configuration notes
7kW, 11kW, and 22kW AC charging options
Socket or tethered cable versions
OCPP, RFID, app, and backend integration options
Wall-mounted and floor-mounted formats
Before inquiry
Confirm single-phase or three-phase input
Choose the correct AC family first: Apollo Type 2 wallbox, MONTA smart AC, floor-mounted commercial AC, or STONE wallbox
Decide socket vs tethered cable and LCD/TFT screen needs
Confirm OCPP backend, RFID, load balancing, and local certification needs
Procurement fit
AC EV chargers are the normal starting point for home, workplace, apartment, hotel, and destination charging because they balance installation cost, parking dwell time, and everyday driver convenience.
Market and standards notes
Select Type 1, Type 2, GBT, or NACS planning by country first, then confirm 7kW, 11kW, or 22kW power, socket or cable output, OCPP, RFID, app control, Dynamic Load Balancing, MID metering, RCD protection, and certification needs.
Implementation risks to confirm
Common risks are undersized grid capacity, unclear backend responsibility, wrong connector standard, cable management problems, outdoor exposure, and inconsistent installation guidance for distributors or installers.
Common buyer questions
Is 22KW Socket TFT Touch Screen suitable for commercial EV charging projects?
22KW Socket TFT Touch Screen can be reviewed for commercial projects when its power, connector, communication, certification, and installation format match the target use case. Share the site and backend requirements before quotation.
Can this AC EV charger be configured for OCPP or smart charging?
OCPP, RFID, app, 4G/WiFi/Ethernet, and remote monitoring requirements should be confirmed by model and project configuration. Amprisen can discuss backend compatibility during the inquiry stage.
What project details should be sent with an inquiry?
Send the target country, connector standard, power level, input phase or grid details, mounting type, communication method, certifications, branding needs, estimated quantity, and expected delivery schedule.